RCDs and RCBOs, explained
Circuit breakers protect cables from too much current. RCDs and RCBOs protect people from current going where it should not.
A residual current device (RCD) monitors the balance of current flowing out and back on a circuit. If some current leaks to earth — through a person, damp insulation or a faulty appliance — the RCD switches off very quickly. One RCD often protects several circuits, which is why it can switch off a whole area when it trips.
Wiring guides explain how circuits are put together and changed, so a quotation or a recommendation is easier to follow.
An RCBO combines an RCD and a circuit breaker in one device for a single circuit. A fault on one circuit then switches off only that circuit, not a group. Both have a test button that checks the mechanism; pressing it periodically confirms the device can still trip.
01In short
The points that matter most
RCDs detect leakage
They protect against shock from earth faults.
RCBOs protect one circuit
Combining leakage and overcurrent protection.
Test buttons matter
They confirm the mechanism still works.
02Detail
How they behave
Shared RCD
One device protecting several circuits; one fault switches them all off.
Per-circuit RCBO
Limits disruption to the faulty circuit.
Nuisance tripping
Cumulative leakage from many appliances can trip a shared RCD.
Different RCD types
Some appliances, such as EV chargers and certain inverters, need a particular RCD type; the manufacturer’s instructions say which.
03Checklist
Practical points
Identify your devices
Look for test buttons on the board.
Test periodically
Press the test button as advised by the manufacturer.
Note what trips
Which device and which circuits go off.
—In practice
Putting it into practice
Identify the devices on your board: an RCD usually has a test button and covers a group of circuits; an RCBO has a test button and covers one. Press each test button periodically as the manufacturer recommends, and note which circuits each one switches off. That knowledge turns a future trip from a mystery into a short list of suspects.
Common mistakes
- Never pressing the test button
- Devices that are never operated can stick in place. Periodic testing confirms the mechanism still moves when a real fault occurs.
- Treating a trip as a nuisance
- An RCD that trips has detected leakage. Find the cause rather than looking for ways to stop it tripping.
04Questions
Questions people ask
- Why does one trip switch off half the house?
- A shared RCD protects several circuits.
- Should every circuit have an RCBO?
- Per-circuit protection reduces disruption; an electrician can advise on upgrading.
- What if the test button does nothing?
- The device may be faulty and should be checked.
- Can an RCD stop every shock?
- It greatly reduces the risk from earth faults, but it does not replace safe practice around electrics and water.
05Related
Related guides
- Circuit breakers, explainedMore on the circuits behind the same problem.
- Labelling a distribution boardMore on the circuits behind the same problem.
- Surface or concealed wiringA related choice for the same kind of work.
- Ring or radial circuitA related choice for the same kind of work.
More electrical wiring guides
- Single-phase and three-phase supplies
- Wiring for an extension, annex or garden room
- MCB or RCBO
- Rewiring in stages or all at once
- Signs that wiring may need replacing
- Rewiring a villa
Getting it looked at
If this needs an electrician, it falls under electrical wiring. Describe what you have noticed on the contact page or call +971 56 181 0106.
This guide sits under electrical wiring. All topics are on the guides page.