Skip to content
Technician

—Checks and maintenance

Checking emergency lighting

Emergency lights only matter in an emergency. Routine checks make sure they work when that moment comes.

Emergency lighting switches on when normal lighting fails, lighting exit routes and signs so people can leave safely. Fittings contain batteries that age, particularly in warm ceilings, and lamps or LEDs that can fail without anyone noticing because the light is normally off.

Maintenance guides describe the checks that find problems while they are still small.

Routine checks usually include brief function tests, where the normal supply is interrupted to see that every emergency fitting lights, and less frequent longer tests to confirm batteries last as required. Results are recorded, and failed fittings or batteries are replaced. The building or authority requirements that apply to the premises set the detail.

01In short

The points that matter most

  • Off until needed

    Failures go unnoticed without testing.

  • Batteries age

    Heat shortens battery life.

  • Record every test

    Records show the system is maintained.

02Detail

What is checked

  • Function tests

    Each fitting lights when its normal supply is interrupted.

  • Duration tests

    Batteries hold the light for the required period.

  • Exit signs

    Legible, lit and pointing the right way.

  • Records

    Dates, results and repairs logged.

03Checklist

Facility manager checks

  • Indicator lights

    Many fittings show a charging indicator; note any that are out.

  • Blocked signs

    Signs hidden by partitions or stock.

  • Test schedule

    Plan tests outside busy hours.

04Questions

Questions people ask

How often should emergency lighting be tested?
At the intervals set by the requirements that apply to the premises; a maintenance plan records them.
Why do batteries fail early?
Heat in ceiling voids and long periods without testing shorten their life.
Does a fit-out affect emergency lighting?
Yes. New partitions can block signs or change routes, so the layout is reviewed.
Can tests disturb staff?
Brief tests are quick; longer tests are scheduled out of hours.

—NEXT

Emergency lighting due for testing?

Tell us the premises and the number of fittings. We will plan testing and keep records.