Earthing and bonding, explained
Earthing is part of what turns an electrical fault into a tripped breaker instead of a shock. Most people never see it.
Earthing provides a path for fault current to flow safely to earth, so that if a live conductor touches the metal casing of an appliance, protective devices operate and disconnect the supply. Without a sound earth, the casing could remain live and give a shock to whoever touches it.
Wiring guides explain how circuits are put together and changed, so a quotation or a recommendation is easier to follow.
Bonding connects metal parts such as water and gas pipes to the earthing system so they stay at the same potential and do not create a shock risk between them. Earthing and bonding are tested as part of an electrical inspection. A tingle from metalwork or appliances is a sign they should be checked.
01In short
The points that matter most
A safe path for faults
Earthing lets protective devices disconnect a fault.
Bonding equalises metalwork
Pipes and metal fittings are connected to avoid shock risks.
Tested at inspection
Earth continuity and bonding are measured.
02Detail
How they are checked
Earth continuity
Testing that each circuit’s earth conductor is intact.
Bonding connections
Checking clamps and conductors on pipework.
Protective device operation
Ensuring devices disconnect faults as intended.
Outdoor metalwork
Garden lights, pool equipment and metal gates near water are places where earthing and bonding matter most and are worth checking after any outdoor work.
03Checklist
Signs to act on
Tingles from metalwork
Taps, rails or appliance casings.
Removed bonding clamps
Often after plumbing work.
Two-pin adaptors
Used to bypass earth pins.
—In practice
Putting it into practice
Look for signs that earthing or bonding may have been disturbed: metal pipes replaced with plastic sections, bonding clamps removed during plumbing work, or two-pin adaptors used to plug in earthed appliances. Report any tingle from metalwork. Earth continuity and bonding can only be confirmed by testing, so include them in any inspection of an older or altered property.
Common mistakes
- Removing a green-and-yellow wire “that does nothing”
- Earth and bonding conductors carry no current in normal use, which is why they get removed by mistake. They matter only when a fault happens.
- Using adaptors that drop the earth
- Two-pin travel adaptors on appliances designed for an earth remove a safety path. Use the correct plug or socket.
04Questions
Questions people ask
- Can plumbing work affect bonding?
- Yes. Replacing metal pipes with plastic or removing clamps can change bonding arrangements.
- Do all appliances need earth?
- Many metal-cased appliances do; double-insulated ones are designed differently.
- Is an earth fault urgent?
- A missing or faulty earth should be addressed promptly.
- What does an earth test involve?
- Measurements of the earth path and of each circuit’s protective conductor, made with the installation safely isolated where required.
05Related
Related guides
- RCDs and RCBOs, explainedMore on the circuits behind the same problem.
- Circuit breakers, explainedMore on the circuits behind the same problem.
- MCB or RCBOA related choice for the same kind of work.
- Surface or concealed wiringA related choice for the same kind of work.
More electrical wiring guides
- Labelling a distribution board
- Single-phase and three-phase supplies
- Wiring for an extension, annex or garden room
- Ring or radial circuit
- Rewiring in stages or all at once
- Signs that wiring may need replacing
Getting it looked at
If this needs an electrician, it falls under electrical wiring. Describe what you have noticed on the contact page or call +971 56 181 0106.
This guide sits under electrical wiring. All topics are on the guides page.